Latest Offers
Special Deals
Compare Product
closeYOUR CART
closePrice | To be announced |
Status | Out Of Stock |
Product Code | 21366 |
Brand | Power Guard |
Main Feature | ||
Load Capacity | 720W | |
Input Voltage | 145-280V | |
Output Voltage | 220/230 VAC +/-10% |
|
Frequency (Battery Mode) | 50/60Hz +/-5% | |
Battery | Automatically Intelligent Battery Management Compatibility with generators, 2 pc with 12V & 8.2Ah | |
Alarm | Beeping Alarm | |
Indications | AC Mode: Green lighting Battery Mode: Red lighting Over Load: Yellow lighting |
|
Output Features | ||
Backup Time | 35-40 Min. (1Pc & 1 Monitor) | |
Transfer Time | 2-6 ms Typical | |
Manufacture Warranty | ||
Warranty | 1 year Under the following conditions, the warranty would not be provided: • UPS burning due to thunder, abnormal overload, insect entrance and others. • If ambient temperature should not be maintained at 20 to 26 degrees Celsius with proper dehumidification. (24/7) • If the product is placed in a dusty and damp place. • In the absence of Generator connectivity Without proper battery charge, the warranty will be void. • Battery swelling and overcharging due to the wrong system voltage setting of the UPS. |
The Power Guard 1200VA PS Offline UPS features Automatic voltage regulation(AVR), High/ Low Voltage Protection, Overload/ Short Protection Cool. This Power Guard UPS featured an input voltage range of 145-280VAC and a frequency of 50/60Hz+/-5%. It offers an output voltage of 220/230VAC+/-10%. It has a transfer time of 2~6 ms (Typical) and a Pure Sine Wave. This Power Guard 1200VA CS UPS indicates AC Mode with Green lighting, Battery Mode with Red lighting, and Over Load Yellow lighting. The Power Guard 1200VA UPS is equipped with a Lead-Acid Maintenance-Free battery. It takes a recharge time of 6 hours up to 90% capacity. It can deliver a backup time of 35-40 mins (Depending on load). The Power Guard 1200VA PS Offline UPS has a 1-year warranty.
Under the following conditions, the warranty would not be provided:
• UPS burning due to thunder, abnormal overload, insect entrance and others.
• If ambient temperature should not be maintained at 20 to 26 degrees Celsius with proper dehumidification. (24/7)
• If the product is placed in a dusty and damp place.
• In the absence of Generator connectivity Without proper battery charge, the warranty will be void.
• Battery swelling and overcharging due to the wrong system voltage setting of the UPS.
Have question about this product? Get specific details about this product from expert.
Get specific details about this product from customers who own it.